en:docs:dos:api:int21:14

Note: This API call is for DOS personality only. Use Family API for portability.

2018/09/07 07:04 · prokushev

Int 21H, AH=14H

Version

1 and higher

Brief

SEQUENTIAL READ FROM FCB FILE

Family API

Input

      AH = 14h
      DS:DX -> opened FCB (see #01345)

Return

Return: AL = status

          00h successful
          01h end of file (no data)
          02h segment wrap in DTA
          03h end of file, partial record read
      Disk Tranfer Area filled with record read from file

Notes

reads a record of the size specified in the FCB beginning at the
        current file position, then updates the current block and current
        record fields in the FCB
      if a partial record was read, it is zero-padded to the full size
      not supported by MS Windows 3.0 DOSX.EXE DOS extender
      

See also

AH=0Fh,AH=15h,AH=1Ah,AH=3Fh“DOS”,INT 2F/AX=1108h

Note

DOS API
Process manager INT 20H, INT 21H: 00H, 25H, 26H, 31H, 34H, 35H, 4CH, INT 22H, INT 27H, INT 28H
File manager INT 25H, INT 26H, INT 21H: 0DH, 0EH, 0FH, 10H, 11H, 12H, 13H, 14H, 15H, 16H, 17H, 19H, 1AH, 1BH, 1CH, 21H, 22H, 23H, 24H, 27H, 28H, 29H, 2EH, 2FH, 32H, 3305H, 36H, 39H, 3AH, 3BH
Character Device I/O INT 29H, INT 21H: 01H, 02H, 03H, 04H, 05H, 06H, 07H, 08H, 09H, 0AH, 0BH, 0AH, 0CH
Signals INT 23H, INT 24H, INT 21H: 3300H, 3301H, 3302H
Memory manager
Date and Time INT 21H: 2AH, 2BH, 2CH, 2DH
Misc INT 21H: 30H, 3306H, 3700H, 3701H, 3702H, 3703H
NLS INT 21H: 3303H, 3304H, 3800H, 3801H
2018/09/04 19:23 · prokushev

en/docs/dos/api/int21/14.txt · Last modified: 2020/12/08 07:34 by prokushev