smartctl 7.2 2020-12-30 r5155 [aarch64-linux-5.4.211] (localbuild) Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: HUH721010ALE601 Serial Number: 1SG0ZB3Z LU WWN Device Id: 5 000cca 26bc071f6 Firmware Version: LHGL0003 User Capacity: 10,000,831,348,736 bytes [10.0 TB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 7200 rpm Form Factor: 3.5 inches Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4 SATA Version is: SATA 3.2, 6.0 Gb/s (current: 3.0 Gb/s) Local Time is: Mon Oct 14 17:31:36 2024 UTC SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x84) Offline data collection activity was suspended by an interrupting command from host. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 93) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 1) minutes. SCT capabilities: (0x003d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000b 100 100 016 Pre-fail Always - 0 2 Throughput_Performance 0x0005 133 133 054 Pre-fail Offline - 100 3 Spin_Up_Time 0x0007 146 146 024 Pre-fail Always - 448 (Average 451) 4 Start_Stop_Count 0x0012 100 100 000 Old_age Always - 264 5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail Always - 0 7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always - 0 8 Seek_Time_Performance 0x0005 128 128 020 Pre-fail Offline - 18 9 Power_On_Hours 0x0012 095 095 000 Old_age Always - 40354 10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 59 22 Unknown_Attribute 0x0023 100 100 025 Pre-fail Always - 100 45 Unknown_Attribute 0x0023 100 100 001 Pre-fail Always - 1095233372415 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 883 193 Load_Cycle_Count 0x0012 100 100 000 Old_age Always - 883 194 Temperature_Celsius 0x0002 150 150 000 Old_age Always - 40 (Min/Max 19/56) 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0 197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always - 0 231 Temperature_Celsius 0x0032 100 100 000 Old_age Always - 0 241 Total_LBAs_Written 0x0012 100 100 000 Old_age Always - 4169316491591 242 Total_LBAs_Read 0x0012 100 100 000 Old_age Always - 5987374086102 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Vendor (0x70) Completed without error 00% 40255 - # 2 Vendor (0x71) Completed without error 00% 40255 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.